xpresstore.blogg.se

Code alarm pro f50
Code alarm pro f50







  1. Code alarm pro f50 software#
  2. Code alarm pro f50 download#

Code alarm pro f50 download#

Incorrect data length, insufficient number of bytesĬonfiguration download error detected (additional info=Modbus register address)ĭuring a configuration download, one or more configuration values were not accepted by the drive. Verify device type including type of power stage. The configuration data contains data from a different device. Request to a module is blocked because the module is currently processing another request.Ĭonfiguration data incompatible with device Power the drive off/on and retry to download the configuration or restore the factory settings.Īn external tool has downloaded a configuration which has an incorrect format. The configuration was only partially transferred to the drive and might be inconsistent now. System not locked for configuration transferĪn external tool has tried to transfer the configuration without locking the drive.ĭuring a configuration download, a communication error or an error in the external tool was detected. This may not work because another tool had already locked the configuration of the drive or the drive is in an operating state that does not allow locking. Verify that you have the correct device type or the correct configuration file.Ī previous file transfer has been aborted.Īn external tool has tried to lock the configuration of the drive for upload or download. The specific type of device does not support this kind of file. Verify that you have the correct device type, in particular type of motor, type of encoder, holding brake. The specific type of device does not support this function or this parameter value. See the chapter Parameters for the parameter that requires a restart of the drive.įunction not available in this type of device Restart the drive to activate the parameter functionality. Only displayed by the commissioning software.Ī parameter modification requires the drive to be powered off and on. Parameter changed that requires a restart of the drive The "First Setup" (FSU) was not run at all or not completed. Value in additional error information shows the Modbus register address of the parameter where the initialization error was detected.īasic configuration of drive required after factory setting System error detected: No bootloader availableĬonfiguration error detected (additional info=Modbus register address)Įrror detected during parameter check (for example, reference velocity value for operating mode Profile Position is greater than maximum permissible velocity of drive).

Code alarm pro f50 software#

The write access level expert is required.Ĭommand not permissible while power stage is activeĬommand not permissible while the power stage is enabled (operating state Operation Enabled or Quick Stop Active).ĭisable the power stage and repeat the command.Īccess occupied by another channel (for example: Commissioning software is active and fieldbus access was tried at the same time).įile cannot be uploaded: Incorrect file IDĭata stored after a power outage is invalid Parameter only accessible at expert level. Write access denied (no access authorization) Write only to parameters that are not read-only.

code alarm pro f50

Parameter write not permissible (READ only) The entered value must be within the permissible value range.Įrror detected by parameter management: Parameter (index) does not exist.Įrror detected by parameter management: Parameter (subindex) does not exist. The value entered was outside of the permissible value range for this parameter.









Code alarm pro f50